What should be paid attention to for ultra-long seamless lines?
Once an ultra-long seamless line is locked, its locking condition is not easy to change due to its ultra-long length. For example, when the locking rail temperature is inaccurate and the axial force is unevenly distributed, only local adjustments can be made, and it is almost impossible to release the entire rail. Therefore, "locking the rail temperature accurately" is particularly important for ultra-long seamless lines.
To this end, it is necessary to do the following:
1. Tracking and monitoring:
When overhauling and replacing rails, the engineering section shall dispatch technical personnel in charge of seamless lines to track and monitor the setting of the locking rail temperature during construction. Whether the basis for the locking rail temperature determined by the construction unit is reliable; whether the measurement of the groove rail temperature and the groove rail temperature of the new rail is accurate and timely; during low-temperature stretching, whether the stretching temperature difference and stretching amount are correctly determined, whether the stretching is uniform, etc., must be carefully monitored, inspected and recorded. Strict acceptance. When the project is accepted, the relevant information on the recording of the locking rail temperature must be complete, and at the same time, it must be checked and verified one by one. If there is any doubt, it must be verified clearly.

2. Final review:
After the project is accepted, the engineering section shall conduct a standard measurement of the rail length table items in the acceptance section, remove suspicious points, and calculate the locked rail temperature value of each section. Then, a final check will be conducted on the tracking and monitoring, acceptance data, and standard measurement, and the locked rail temperature will be used as the basis for future management.
3. Daily monitoring:
In daily management, the creeping observation piles and the marking points for rail length calibration should be regularly observed and checked against each other. If displacement is found between the two observation piles, the marking points between the two observation piles will be further measured to check the actual section where the displacement occurs. After verification, local stress adjustment will be carried out to make it uniform.