Why Protection of Finished Rail Anchors Matters
A rail anchor, also called an anti-creeper, is a spring steel clamp that grips the rail foot and bears against the side of the sleeper to prevent longitudinal rail movement caused by temperature change, traction and braking. Because the anchor is installed in the ballast zone, it is exposed to moisture, abrasive ballast dust, de-icing salts and repeated impact. Protection applied after the anchor leaves the forming line therefore determines how long the component keeps its grip.
Surface Preparation
Coating adhesion depends almost entirely on surface preparation. The sequence is degreasing to remove drawing oils and forming lubricants, descaling and blasting to a preparation grade equivalent to Sa 2 and a half of ISO 8501-1, and immediate transfer to the coating stage to avoid flash rusting. Sharp edges on the anchor jaws and on any punched holes should be smoothed before coating, because thin or broken coatings at an edge are the starting point for corrosion fatigue.
Coating Systems
| System | Reference | Typical use |
|---|---|---|
| Hot dip galvanising | ISO 1461 | General track use; minimum average 85 micrometres and minimum local 70 micrometres for steel 6 mm and above |
| Mechanical zinc coating | ASTM B695 class 50 | Threaded or close tolerance features where hot dip build up is a problem |
| Zinc rich primer with topcoat | ISO 12944 corrosivity C4 and C5-M | Coastal, tunnel and industrial environments |
| PVC or epoxy powder coating | Supplier specification | Added abrasion resistance in ballast contact areas |
| Colour marking paint | Supplier specification | Batch identification rather than corrosion protection |
Note that coating systems applied to a hardened spring component must be compatible with the service temperature of the part. Baking temperatures that exceed the tempering temperature of the spring steel will reduce jaw clamping force, so coating processes are usually selected so that the component is never heated above its tempering range.
Materials Behind the Finished Anchor
Rail anchors are commonly produced from silicon-manganese spring steel such as 60Si2MnA, from quality carbon steel such as grade 45, or from ductile iron for specific jaw designs. Typical chemical composition ranges are shown below.
| Material | Standard | Typical chemical composition (percent by mass) |
|---|---|---|
| 60Si2MnA | GB/T 1222 | C 0.56 to 0.64, Si 1.60 to 2.00, Mn 0.60 to 0.90, Cr 0.35 max, P 0.03 max, S 0.03 max |
| 45 | GB/T 699 | C 0.42 to 0.50, Si 0.17 to 0.37, Mn 0.50 to 0.80, Cr 0.25 max, P 0.035 max, S 0.035 max |
| QT500-7 | GB/T 1348 | C 3.60 to 3.80, Si 2.50 to 2.90, Mn 0.60 max, P 0.08 max, S 0.025 max |
Ductile iron grade QT500-7 to GB/T 1348 is specified with a minimum tensile strength of 500 MPa, a minimum 0.2 percent proof strength of 320 MPa and a minimum elongation of 7 percent. Spring steel anchors are hardened and tempered to develop the jaw force needed to resist rail creep without cracking under repeated cycling.
Handling, Packing and Storage
Coated anchors should be packed so that coatings are not damaged in transit. Components are normally banded in bundles with separators, kept off damp ground on pallets, and stored under cover where possible. Bundles should not be dropped or dragged, because mechanical damage to a coating cannot be repaired on site and any bare area becomes a corrosion initiation point. Where long storage is expected in a humid climate, protective wrapping is normally specified.
In-Service Precautions
Installed anchors should be checked for correct seating against the sleeper face, for jaw damage and for coating loss. Overloading and excessive vibration accelerate loosening, so components must be matched to the rail section actually in track and replaced during rail renewal rather than re-clamped on a new section. When an anchor is replaced, the substitute should match the original specification and be protected to the same coating class, because mixing protection levels in one zone leads to uneven corrosion and premature failure of the weaker part.
Frequently Asked Questions
Q: What are finished rail anchors protected against?
A: Mainly atmospheric corrosion in the ballast zone, abrasion from ballast movement, and fatigue cracking at the jaws. Coating and correct hardening address the first two and part of the third.
Q: Which coating thickness is required?
A: For hot dip galvanising to ISO 1461 on steel 6 mm and above, a minimum average coating thickness of 85 micrometres and a minimum local thickness of 70 micrometres.
Q: Can hot dip galvanising damage a spring steel anchor?
A: The zinc bath operates near 450 degrees Celsius, which is below the normal tempering range of spring steels, but process time and subsequent cooling should be controlled to avoid loss of jaw force. Where risk remains, mechanical zinc to ASTM B695 class 50 avoids the hot dip step.
Q: What material is used for rail anchors?
A: Silicon-manganese spring steel such as 60Si2MnA to GB/T 1222, quality carbon steel such as grade 45 to GB/T 699, and ductile iron QT500-7 to GB/T 1348 for particular designs.
Q: How should anchors be stored before installation?
A: Keep bundles on pallets, under cover, clear of standing water, and handle them without dropping or dragging so that the coating is not scratched.
Q: What indicates that an anchor must be replaced?
A: Loss of jaw force shown by rail creep past the anchor, visible cracking at the bend radii, deep coating loss with pitting, or a mismatch between the anchor and the rail section in track.