Fish Plates Are Not Always Required
Fish plates, also called joint bars, are not mandatory for GOST P65 rails in every track design. Modern railway engineering offers two distinct track methodologies, and the choice depends on the design framework and operating requirements. P65 rail is explicitly designed to support both approaches.
In continuous welded rail construction, individual P65 sections are joined permanently by flash-butt welding or aluminothermic welding to form an uninterrupted rail string that can extend for kilometers. In this configuration fish plates are intentionally eliminated. In jointed track construction, however, fish plates are mandatory because they are the only component that holds the rail ends in alignment and transfers load across the joint.
Continuous Welded Rail Without Fish Plates
High-density mainlines, high-speed corridors, and heavy-haul freight lines almost always use continuous welded rail. Removing the mechanical joint eliminates the weakest point of the track structure and the impact forces that occur at every joint. Welded track also reduces wheel and substructure wear, lowers maintenance work, and prevents the dynamic stress that pulverizes ballast around traditional joints.
The P65 profile supports this design because it has a high linear mass of 64.72 kg per meter and a web thickness of 18 mm. This robust section provides the rigidity needed to manage the longitudinal thermal stresses generated in continuous welded rail without buckling in summer heat or pulling apart in winter cold.
Where Fish Plates Remain Mandatory
Several specific zones of a P65 network still depend on mechanical joints. Temporary track and repair zones use fish plates when mobile welding rigs cannot be deployed quickly, keeping the line operational under speed restrictions. Insulated joints for signaling are another essential case: where audio-frequency track circuits are not used, engineers install insulated rail joints with bonded composite fish plates to block electrical current between track blocks.
Sharp curves and special trackwork also favor jointed panels. In turnouts, switch splits, and tight curves within industrial yards, jointed rail simplifies maintenance and replacement. Buffer zones near non-ballasted bridges and open-deck spans use jointed track with expansion joints to decouple the thermal movement of the bridge structure from the mainline.
| Track Zone | Jointing Method | Reason |
|---|---|---|
| Mainline and high-speed corridors | Continuous welded rail | Eliminates joint impacts and lowers maintenance |
| Temporary repair zones | Fish plates | Rapid deployment without welding equipment |
| Signaling locations | Insulated rail joints | Electrical isolation for track circuits |
| Turnouts and sharp curves | Jointed panels | Simplified maintenance and replacement |
| Bridge approaches | Jointed track with expansion joints | Decouples bridge thermal movement |
Advantages of Rail Joint Bars
Where fish plates are used, they provide four core functions. They maintain structural alignment between rail ends, preventing vertical and horizontal misalignment that could cause derailment. They distribute the downward wheel pressure across the joint so that no single point carries the full load. They leave a controlled gap that allows safe thermal expansion and contraction without track buckling. And when configured as insulated rail joints, they isolate electrical signaling circuits so that broken rails and train positions can be detected reliably.
Specialized compromise bars even allow a railroad to transition between rails of different heights or weights in the same line, and jointed sections create natural break points that are convenient for track repair crews.
Maintenance of Jointed P65 Track
Jointed sections require regular attention. Bolt torque must be verified periodically, the fishing surfaces should be lubricated to allow natural thermal movement, and routine rail grinding prevents the rail ends from developing severe spalling. Standard P65 fish plates are governed by GOST 8193 and GOST 19128, and factory bolt holes in the rail web are typically drilled to 34 mm diameter to accept high-tensile M30 joint bolts with clearance for thermal movement.
Frequently Asked Questions
Why are fish plates still required if P65 track can be completely welded? They are needed for insulated joints that isolate signaling circuits, for turnouts where rails must be replaced periodically, and as a rapid repair solution over damaged track sections.
What is the standard bolt hole diameter for a GOST P65 rail web? Under GOST P51685 practice, the factory bolt holes are typically drilled with a 34 mm diameter to accept standard high-tensile M30 joint bolts with clearance for seasonal expansion.
Can R65 fish plates fit a lighter 50 kg Russian standard rail? No. Fish plates are precision-contoured to match the height, web radius and fishing angles of one specific profile, so using R65 joint bars on a lighter profile produces a loose connection and poor alignment.
How does the 18 mm web thickness help the joint? The thick web provides extra steel around the bolt holes, which drastically reduces the risk of star cracks forming from the hole edge under cyclical loading.
Are custom bolt configurations available for GOST P65 rail? Yes. Standard production follows traditional 4-hole or 6-hole drilling arrangements, but rail ends can be custom-machined or supplied blank to match regional engineering specifications.
What maintenance keeps a jointed P65 track safe? Regular inspection of bolt torque, lubrication of the fishing surfaces for thermal movement, and routine grinding to prevent spalling at the rail ends.